LUXALON® WIDE PANEL 300C LAY-ON CORRIDOR SYSTEM SPECIFICATION
PART 1: LAY-ON SYSTEM GENERAL
1.1 INTRODUCTION
Supply and fix Luxalon® 300 C Wide Panel Lay-on wall panels, as manufactured bij Hunter Douglas Architectural Products.
1.2 DESCRIPTION OF THE SYSTEM
The system will consist of panels which are laid on wall angles.
PART 2: PRODUCT
________m2 Luxalon® 300C Wide Panel Lay-on Ceiling consisting of:
2.1 PANELS
Panels to be rollformed from 0.7 mm thick stove enamelled aluminium strip or 0.6 mm thick stove enamelled galvanised steel strip, plain or perforated with or without non-woven acoustic textile.
The 29 mm high upstands at the panel ends to give enhanced rigidity. The 300 mm wide panels to feature 5 mm bevelled edges to form visually closed V-groove joints.
Panels to be manufactured from prepainted, stove enamelled aluminium, alloy EN-AW-3005 or equivalent (according to EN 1396 and ECCA)/from prepainted, stove enamelled galvanized steel Z100 or equivalent metal coating (according to EN10169, part 3 and ECCA). Panels to have a length of______ mm. (manufacturer availability 1000-2400 mm and on request < 1000 mm).
2.2 SUSPENSION
Standard bandraster profiles are to be used for suspension: Non Luxalon® specifications from the related supplier.
PART 3: ADDITIONAL SPECIFICATIONS
3.1 PERIMETER PROFILES
- Wall L-profile, 45 x 18.5 mm made of 0.8 mm thick steel
- Wall-W-profile, 45 x 21 x 21 x 18.5 mm made of 0.8 thick steel
3.2 PERFORATIONS
Manufacturer shall supply all 300C Lay-on panels with the following perforation specifications:
- Ø1.5 mm, ∆ 3 mm, open area 23 %
- Ø2.0 mm, ∆ 5 mm, open area 15%
Perforated panels to have a nominal plain border of 8.5 mm along the longitudinal panel direction to assure maximum flatness and product stability.
3.3 ACOUSTICS
Manufacturer shall supply acoustic non-woven tissue, thickness 0.2 mm and factory applied inside the panels. Alternatively the installer can place individual, wrapped mineral wool pads.
3.4 COATING
Architect will make a colour selection from the standard Hunter Douglas colour range for Luxalon® 300C Wide panels code no._______or a special colour will be made to match.
The coating will consist of a tough and durable 2-layer polyester finish in nominal thickness of 20 microns, applied in a continuous coil-coating process ensuring uniform coating and absolute adhesion.
3.5 INSTALLATION
All materials shall be installed in strict compliance with all local codes, ordinances and manufacturers recommandations including specific additional requirements as may be called for in the specifications or shown on the drawings.
3.6 SUBSTITUTIONS
Ceiling installers wishing to submit proposals on systems other than the Luxalon® 300C Wide Panel System shall, at least 20 days in advance of the bid date, submit to the architect complet descriptive information of the total system concept and performance data tests made as a system . In addition include a list of similar installations of the proposed substitution. If approval is made an addendum will be issued enumerating such approved system as herein set forth.